Performance Data | |
---|---|
IEC 62052-31 Capability | UC3 at 120A/276V |
Rated UC3 Load | 120A |
Nominal Voltage | 230V |
Frequency | 50Hz |
Contact Materials | AgSn02 |
Contact Form | Normally Closed |
Electrical Endurance | 5000 Cycles (Resistive PF1), then 5000 Cycles (Inductive PF0.5) 100 Amps, 276 Volts |
Pulse width Requirement | Min. 50ms |
Insulation Information | |
---|---|
AC Dielectric Strength | |
Coil to Contact on new switch | 4KV |
New switch – open contacts | 2KV |
After UC3 electrical Endurance | 1KV |
DC Impulse Dielectric | |
Coil to Contact on new switch | 8KV |
New switch – open contacts | 4KV |
After UC3 electrical Endurance | 2KV |
Distance Between terminals | 8.75mm |
Technical Information | |
---|---|
Switch Circuit Resistance | <250 micro Ohms |
Product Weight | 52g |
Product Dimensions | 37mm x 43mm x 22mm |
Mechanical Endurance | 100K cycles (360 cycles per min.) |
Shock test | 50g |
Vibration Test | 10-150Hz, 20m/s2 acceleration |
Accelerated Life Test | 85O C, 85%RH, 600 Hours |
Flammability Rating | V0 |
Customisation | Fully customisable for efficient integration into Smart Meters |