Performance Data | |
---|---|
IEC 62052-31 Capability | UC3 at 60A/276V |
Max. Switching Current | 60A |
Max. Carrying Current | 90A |
Nominal Voltage | 230V |
Contact Materials | AgSn02 |
Contact Form | Normally Closed |
Electrical Endurance | 5000 Cycles (Resistive PF1), then 5000 Cycles (Inductive PF0.5) 60 Amps, 230 Volts |
Pulse width Requirement | Min. 50ms |
Insulation Information | |
---|---|
AC Dielectric Strength | |
Coil to Contact on new switch | 4KV |
New switch – open contacts | 2KV |
After UC3 electrical Endurance | 1KV |
DC Impulse Dielectric | |
Coil to Contact on new switch | 8KV |
New switch – open contacts | 4KV |
After electrical Endurance | 2KV |
Distance Between terminals | 6.80mm |
Technical Information | |
---|---|
Switch Circuit Resistance | <400 micro Ohms |
Product Dimensions | 30mm x 38mm x 16.5mm |
Mechanical Endurance | 100K cycles (360 cycles per min.) |
Flammability Rating | V0 |
Customisation | Fully customisable for efficient integration into Smart Meters |